Deep-Sea Underwater Cable
Deep-Sea Underwater Cable
Deep-Sea Underwater Cable
Deep-Sea Underwater Cable
Deep-Sea Underwater Cable
Deep-Sea Underwater Cable
Deep-Sea Underwater Cable

Deep-Sea Underwater Cable

BS-SSC-6CORE-BLK-MXA1

Regular price$14.39

50 Units Available for Quick Ship - Ships in 1-2 Business Days

Additional Units Made to Order - Ships in 2-5 Weeks

Shipping calculated at checkout.

Option

Deep-Sea Underwater Cable is a rugged and flexible underwater cable designed for delivering power to subsea devices such as thrusters, LED lights, and sensors. It features stranded copper cores that offer excellent flexibility and resistance to vibration, and a tough polyurethane (PUR) outer jacket that provides high durability against abrasion, seawater, and oil. The cable is available in multiple core variants and is optimized for use with cable penetrators or gland cable penetrators to ensure a secure, watertight seal. Color-coded wires simplify termination and ensure easy identification during installation.

Sold in 1-meter (3.28-foot) increments. Quantities are entered in 1-meter units.

A compatibility guide is provided below to assist with selecting appropriate Blu-Sub penetrators & gland penetrators that match the cable diameter.

For added strength, the cable includes an internal Kevlar reinforcement layer, which helps prevent stretching and improves tensile load capacity during deployment or recovery. This makes it ideal for both fixed and mobile underwater systems requiring reliable, high-performance power delivery in challenging marine environments.

Standard spool length is 50 meters (164 feet), but longer continuous lengths may be available upon special request. Please contact us if you require extended runs beyond 50 meters (extended lead times may apply).

Material Tinned copper conductors, double-layer PUR insulation, Kevlar and non-woven filler, black polyether PUR jacket
Weight N/A
Color Black jacket; conductor colors vary by specification (e.g., Red, Black, Yellow)
Depth Rating Up to 1,000 m / 3,281 ft (with appropriate waterproofing at cable ends)
Dimensions Outer diameter varies by specification:
• 3x16AWG: 7.5 mm ±0.15
• 6x24AWG: 7.0 mm ±0.15
• 4x28AWG: 5.2 mm ±0.15
• 2x16AWG+4x26AWG: 8.0 mm ±0.15
• 2x24AWG+2x26AWG: 7.5 mm ±0.15
• 3x20AWG: 6.0 mm ±0.15

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

DESCRIPTION

Cable Penetrators & Gland Cable Penetrators Compatibility Guide:

Item Deep-Sea Cable Penetrators Deep-Sea M10 Gland Cable Penetrators Low-Depth M10 Gland Cable Penetrators Mid-Depth M8 Gland Cable Penetrators
3-Core (16AWG) Underwater Cable
BS-SSC-3CORE-BLK-16A1
M10x1 Aluminum
BS-SSC-CBLPN-BLK-10A1
7.8 × 5.6 Stainless Steel
BS-SSC-GLPEN-SSX-78A1
7.8 × 5.6 Aluminum
BS-SSC-GLPEN-ALU-78A1
7.8 × 5.6 Copper
BS-SSC-GLPEN-NPB-BRA1
Not Compatible
6-Core (24AWG) Underwater Cable
BS-SSC-6CORE-BLK-24A1
M10x1 Aluminum
BS-SSC-CBLPN-BLK-08A1
7.2 × 4.6 Stainless Steel
BS-SSC-GLPEN-SSX-72A1
7.2 × 4.6 Aluminum
BS-SSC-GLPEN-ALU-72A1
7.2 × 4.6 Copper
BS-SSC-GLPEN-NPB-BRA2
Not Compatible
4-Core (28AWG) Underwater Cable
BS-SSC-4CORE-BLK-28A1
M6x1 Aluminum
BS-SSC-CBLPN-BLK-06A1
5.6 × 3.4 Stainless Steel
BS-SSC-GLPEN-SSX-56A1
5.6 × 3.4 Aluminum
BS-SSC-GLPEN-ALU-56A1
5.6 × 3.4 Copper
BS-SSC-GLPEN-NPB-BLA1
Not Compatible
6-Core (2x 16AWG / 4x 26AWG) Underwater Cable
BS-SSC-6CORE-BLK-MXA1
M10x1 Aluminum
BS-SSC-CBLPN-BLK-10A1
8.4 × 5.9 Stainless Steel
BS-SSC-GLPEN-SSX-84A1
8.4 × 5.9 Aluminum
BS-SSC-GLPEN-ALU-84A1
8.4 × 5.9 Copper
BS-SSC-GLPEN-NPB-BRA3
Not Compatible
4-Core (2x 24AWG / 2x 26AWG) Underwater Cable
BS-SSC-4CORE-BLK-MXA1
M10x1 Aluminum
BS-SSC-CBLPN-BLK-10A1
7.8 x 4.1 Stainless Steel
BS-SSC-GLPEN-SSX-78A2
7.8 x 4.1 Aluminum
BS-SSC-GLPEN-ALU-78A2
7.8 x 4.1 Copper
BS-SSC-GLPEN-NPB-BRA4
Not Compatible
3-Core (20AWG) Underwater Cable
BS-SSC-3CORE-BLK-20A1
M8x1 Aluminum
BS-SSC-CBLPN-BLK-08A1
6.4 × 4.3 Stainless Steel
BS-SSC-GLPEN-SSX-64A1
6.4 × 4.3 Aluminum
BS-SSC-GLPEN-ALU-64A1
6.4 × 4.3 Copper
BS-SSC-GLPEN-NPB-BLA2
M8 Aluminum
BS-SSC-THGLP-ALU-08A1


Large Top Image

Cable Penetrator Options

Sold Separately

Blu-Sub offers four types of cable penetrators designed to work with its subsea power and communication cables, each suited for different underwater applications:

Deep-Sea Cable Penetrators – Standard body design for high-pressure, full-depth deployments. Depth Rating: Up to 1,000 m / 3,281 ft

Deep-Sea M10 Gland Cable Penetrators – Threaded M10 penetrators with compression glands for added strain relief and modular housing use. Depth Rating: Up to 1,000 m / 3,281 ft

Low-Depth M10 Gland Cable Penetrators – Compact and cost-effective option for shallow water or low-pressure systems. Depth Rating: Up to 100 m / 328 ft

Mid-Depth M8 Gland Cable Penetrators – Slim-profile solution for small enclosures or tight mounting areas. Depth Rating: Up to 300 m / 984 ft

A compatibility guide is provided above to help you choose the correct model based on your cable and sealing needs.

Compatible With: Deep-Sea Cable Connector Systems

Sold Separately

Deep-Sea Cable Connectors – Female Socket & Male Plug
Modular in-line connectors designed to terminate underwater cables with sealed male or female plug ends. These connectors allow the Deep-Sea Underwater Cable to form reliable, removable connections between subsea devices.

Deep-Sea Cable Connectors – M10 Bulkhead
Panel-mount connector that allows the cable to interface directly with enclosures or end-caps. Requires a matching male plug from the Deep-Sea Cable Connectors line to complete a watertight connection.

Deep-Sea Cable Connectors – Dummy Sealing Cap
Used to seal and protect unused connector ends when not in operation. Prevents moisture ingress and maintains system waterproofing in storage, transit, or standby conditions.

Compatible With: Subsea M10 Coupling Tube

Sold Separately

This cable is fully compatible with the Subsea M10 Coupling Tube, which allows two lengths of cable to be joined securely using penetrators and potting compound, or enables repositioning of penetrator-mounted components such as lights, switches, or sensors to more accessible locations.

SHIPPING LIST

Underwater Cable:
Cable of corresponding specifications × N meters

TECHNICAL SPECIFICATIONS
Specification 3-Core (16AWG) 6-Core (24AWG) 4-Core (28AWG) 6-Core (2x 16AWG / 4x 26AWG) 4-Core (2x 24AWG / 2x 26AWG) 3-Core (20AWG)
Conductor Tinned Copper Wire 169×0.10 Tinned Copper Wire 19×0.127 Tinned Copper Wire 13×0.10 Tinned Copper Wire 104×0.127; 19×0.1 Tinned Copper Wire 19×0.127; 19×0.1 Tinned Copper Wire 119×0.08
Insulation Double-Layer PUR
Insulated Wire Diameter (mm) 2.4±0.1 1.4±0.1 1.2±0.1 2.8±0.1; 1.2±0.1 1.6±0.1; 1.4±0.1 1.8±0.1
Filler Kevlar, Non-Woven
Jacket Material Polyether PUR
Jacket Thickness (mm) 1.15 1.4 1.0 1.1 1.3 1.0
Jacket Color Black
Conductor DC Resistance ≤13.8Ω/km ≤75Ω/km ≤185Ω/km <13.7Ω/km; <122Ω/km ≤75Ω/km ≤32Ω/km
Test Voltages 1000V/min(AC) 1000V/min(AC) 700V/min(AC) 1000V/min(AC) 1000V/min(AC) 1000V/min(AC)
Insulation Resistance (20°C) ≥20MΩ·km ≥20MΩ·km ≥20MΩ·km ≥20MΩ·km >10MΩ·km ≥20MΩ·km
Rated Voltage Power Line 300V
Minimum Bending Radius (Fixed) 4D (D = Cable Diameter)
Minimum Bending Radius (Occasional Movement) 7.5D (D = Cable Diameter)
Core Color Red, Black, Yellow White, Yellow, Green, Red, Blue, Brown White, Black, Red, Green Red, Black, Blue, Orange, Green, Brown Red, Black, White, Green Red, Black, Yellow
Overall Cable Diameter (mm) 7.5±0.15 7±0.15 5.2±0.15 8±0.15 7.5±0.15 6.0±0.15


How to waterproof the cable ends?
Waterproofing methods depend on specific requirements, considering factors such as whether it is detachable, waterproof depth, lifespan requirements, environmental conditions, and connection methods (line-to-line, watertight enclosure outlet), etc.
- Simple Waterproofing Treatment: Use cable penetrator, resin potting, etc.
- Waterproofing Treatment within 1000 meters depth: Traditional encapsulation materials sealing, such as gel beads, gland heads used in pump cables, etc.
- Deepwater Waterproofing Treatment: Sealing with vulcanized rubber, pressing waterproof connectors, fixed joints made of polyurethane, etc.

What is the minimum order quantity?
The minimum order quantity is 1 meter, and prices decrease with larger quantities. Please contact us for bulk discount on large order volumes.

How to strip the cables?
Cable stripping can be done using diagonal pliers or a knife blade. Stripping tools or pneumatic/electric wire strippers are used for batch cutting. Kevlar inside may require separate cutting.

What happens if the bending radius exceeds the minimum bending radius?
There is a risk of cable jacket rupture with prolonged excessive bending, and prolonged exposure to ultraviolet radiation should also be avoided.

What is the operating temperature range?
The long-term operating temperature is -20°C to 80°C, and the storage temperature is -20°C to 50°C.

Can it be used if the cable jacket is damaged?
A damaged cable jacket may lead to short circuits or open circuits and can affect waterproofing.



Recently viewed